Magnetic Brake Motors & Gear Motors

Electronic Instant Brake

SB Series

SB Series

Braking Principles
Electronic brake circuit is designed to introduce pulsated direct current rectified by the half wave into motor, to produce directional magnetic field and stop the motor instantly. Brake current is produced by the controller and introduced into motor in a very short time only. The time frame for brake current enter into the motor (approx. 0.5 seconds) is controlled by timing circuit inside the controller. No friction created between parts, therefore lifespan is extended.

Operating Frequency and Limitation
Although the "IN" model could be used for inch movement, a rise in temperature would result from frequent start-stop action of the motor. Please suspend operation temporally if the surface temperature of the motor exceeds 90°C.

Wiring